What was found
THREE FASTENER HOLES FOUND CRACKED, DURING OPEN-HOLE HFEC INSPECTION AT LT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN XORS 683.4 AND XORS 713.6. REPAIRED IAW SRM 57-20-02, REPAIR 5, FIGURE 201, REVISION 53 AND EA 1-5710-122470, REVISION B, PART 3. REPAIR CLASSIFIED MINOR PER GMM 6-2-100 REVISION 118.