As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AT TOP OF DESCENT ENG 3 FADEC FAULT LEVEL ONE ALERT & ENG 3 FLAMED OUT. RAN CHECKLISTS & RELIT ENG 3. CONTINUE ARRIVAL WITH ALL ENGINES OPERATING, LT IGNITER IN OVERRIDE WITH A & B SELECTED. ENG 3 FADEC FAULT REMAINED ON UNTIL ENG SHUT DOWN NORMALLY ON GROUND. HAD NR 3 ENG FADEC FAULT CODES ON CHANNEL B OF NR 3. R & R NR 3 ECU IAW AMM 73-21-02-04-1. ALL REQUIRED CHECKS WERE GOOD. ACFT OK FOR SERVICE. ACCOMPLISHED HIGH POWER RUN UP PER JRH. BLEEDS OFF ENG PARAMETERS ARE NORMAL.