What was found
AFT CARGO PIT AT STRINGER 22L, STRINGER HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53 FIG 101 DETAIL II. REPAIRED STRINGER IAW SRM 53-00-03 FIG 201, REPAIR NR 2 AT STATION 1460 - 1475, STRINGER 22L.