What was found
MAIN DECK STATION 1060 BETWEEN STRINGER 16R TO STRINGER 17R, FRAME AFT SIDE HAS CORROSION. REMOVED DAMAGED FAILSAFE CHORD, CORRODED, IAW SRM 51-40-02. FABRICATED NEW FAILSAFE CHORD PN FX-144N1107-36 STAM TRAVELER T14 1046452 IAW DWG 144N1107-36. INSTALLED NEW FAILSAFE CHORD IAW SRM 51-40-02, AT STATION 1060 STRINGER 9R - 18R.