As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXTERNAL FUSELAGE SKIN DENT STATION 1560 - 1580 BETWEEN STRINGER 27L TO STRINGER 28L. CHECKED DENT LIMITS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01. A Y RATIO AT 14.29. CUT OUT DAMAGE L=2.30 INCHES & W = 1.60 INCHES & INSTALLED REPAIR DOUBLER IAW SRM 53-00-01 FIG 201 REPAIR 16. CAT B REPAIR AT STATION 1560 - 1580 BETWEEN STATION STRINGER 27L - STRINGER 28L.