What was found
CREASE BEAM UPPER SURFACE CORRODED BS 1040 - 1020, RT SIDE. REMOVED CORROSION IAW SRM 51-10-02 AND FOUND OUT OF LIMITS IAW SRM 53-40- 13, FIG. 101, DETAIL VII. REMOVED AND REPLACED CREASE BEAM INNER ANGLE BS 900-1040 IAW SRM 51-40-02 AND DWGS 144N5152, SH. 1 AND 144N5140, SH. 4. MAJOR REPAIR.