What was found
MAIN DECK CARGO FLOORBEAM UPPER TEE HAS AREAS OF CORROSION, BS 1600. FOUND OUT OF LIMITS PER SRM 53-00- 51, FIG. 101, DETAIL VI. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-02 AND DWG 146N5087 BS 1600, LBL 63 - RBL 63. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CARGO FLOORBEAM UPPER TEE HAS AREAS OF CORROSION, BS 1600. FOUND OUT OF LIMITS PER SRM 53-00- 51, FIG. 101, DETAIL VI. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-02 AND DWG 146N5087 BS 1600, LBL 63 - RBL 63. MAJOR REPAIR.