What was found
RIGHT WING LE IS CRACKED BETWEEN NR 4 & NR 5 LE SLATS. REMOVED ACCESS PNL AFT OF CRACK. PNL IN COURIER AREA. REMOVED EXISTING FASTENERS & CUT OUT DAMAGE AREA IAW SRM 57-10-00 FIG 68 SHEET 1. COMPLIED WITH HFEC OF CUT OUT AREA IAW NDT SPM PART 6 20-30-00, NO DEFECTS NOTED. FABRICATE DOUBLER AS .063 TITANIUM & MATERIAL FOR FILLER AS 7075-T6 .090, VERIFIED MATERIAL. REPAIR DOUBLER & FILLER, OK TO INSTALL IAW SRM 57-10-00. INSTALLED REPAIR IAW SRM 57-10-00 FIGURE 68 SHEET 1 & SRM 51-38-01 FOR ONE ALTERNATE FASTENER. REQUIRES PRIME & PAINT. PRIMED & PAINTED REPAIR DOUBLER IAW DC-10 SRM 51-21-02 VOL.2. EL REMOVED TO FOM FOR REPAIR NEEDS TO BE INSTALLED.