What was found
POSSIBLE CRACK RT WING SLAT CUT OUT SEVEN INCHES FROM WING TIP. VERIFIED CRACK IN RT WING SLAT CUT OUT WITH HFEC IAW NDT SPM PT 6, CRACK APPROX 3/4 INCH LENGTH. CUT OUT CRACK IAW SRM 57-10-00. PERFORMED HFEC INSPECTION TO CUT OUT IAW NDT SPM PT 6, NO DEFECTS NOTED. VERIFIED MATERIALS & FABRICATED DOUBLER & FILLER IAW SRM 57-10-00 FIG 68 PO. TREATED & PRIMED AREA & REPAIR COMPONENTS. INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 57-10-00 FIG.68.