What was found
AFT PIT, BS 1460 STRINGER 23L TO 27L FRAME INBD FLANGE CORRODED. FOUND OUT OF LIMITS IAW SRM 53-00-07, FIG. 101, DETAIL II. REMOVED AND REPLACED FRAME IAW SRM 51-40-02 AND DRAWING 146N1029. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT, BS 1460 STRINGER 23L TO 27L FRAME INBD FLANGE CORRODED. FOUND OUT OF LIMITS IAW SRM 53-00-07, FIG. 101, DETAIL II. REMOVED AND REPLACED FRAME IAW SRM 51-40-02 AND DRAWING 146N1029. MAJOR REPAIR.