As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LOWER CTR CARGO COMPARTMENT BILGE AREA STA=1721 X=5 SHEAR CLIP SURFACE FOUND WITH MINOR CORROSION. CORROSION ON SHEAR CLIP AT LOWER CENTER CARGO COMPARTMENT BILGE AREA STATION Y=1721, X=5 REMOVED AS PER SRM 51-31-01 VOLUME II REVISION 101. NEW SHEAR CLIP FABRICATED AS PER DRAWING ADA0112 REVISION R AND INSTALLED AS PER SRM 51- 31-01 VOLUME II REVISION 101. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 122.