As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LOWER CTR CARGO COMPARTMENT BILGE AREA AT STATION Y=1741 X=5 SHEAR CLIP SURFACE FOUND MINOR CORROSION. CORROSION AT LOWER CENTER CARGO COMPARTMENT BILGE AREA SHEAR CLIP STA Y=1741, X=5 REMOVED AS PER SRM 51-31-01 VOLUME II REVISION 101. NEW SHEAR CLIP FABRICATED AS PER DRAWING AFA0010 REVISION L AND INSTALLED AS PER SRM 51-31-01 VOLUME II REVISION 101. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 122.