What was found
AFT CARGO COMPARTMENT STATION 1868 LT X=36.00 FLOOR LINE, FLOORBEAM HAS MULTIPLE HOLES WITH UNACCEPTABLE SPACING BETWEEN HOLES. FABRICATED & INSTALLED REPAIR ANGLE IAW SRM 53-00-01 FIG 9 SHT 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPARTMENT STATION 1868 LT X=36.00 FLOOR LINE, FLOORBEAM HAS MULTIPLE HOLES WITH UNACCEPTABLE SPACING BETWEEN HOLES. FABRICATED & INSTALLED REPAIR ANGLE IAW SRM 53-00-01 FIG 9 SHT 7.