Service difficulty report · Dump Valve · Doug MD1010F

Difficulty date
September 11, 2014
Submitted
September 15, 2014
Operation
Air carrier
Aircraft
N390FE
Make and model
Doug MD1010F
Aircraft serial
46624
Aircraft time
87,541 hours, 36,568 cycles
Part
Dump Valve
Part number
AV16B1926C
Part serial
G01080
Condition
Failed
Location
Fuel System
Part time
24,533 hours, 11,618 cycles
Stage of operation
CR
How discovered
O
Nature of condition
K
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT WING DUMP VLV FAILED TO CLOSE AFTER DUMP TERMINATION. RIGHT FUEL DUMP VLV SYS WIRING CHECKED FROM RT FUEL DUMP VLV M1-89 TO FUEL SYS CONTROLLER. RT FUEL DUMP VLV TO FUEL SYS CONTROLLER, RT FUEL DUMP VLV TO 1, 2, 3 VIA CONTINUITY & INSULATION CHECKED NORMAL IAW WDM 28-31-02. R & R RT WING DUMP VLV. REMOVED AVIONIC COMPARTMENT LT SIDE COOLING RACK DUCT. INSTALLED AVIONICS COOLING DUCT IN FWD AV COMPARTMENT AS REQUIRED, OPERATIONS CHECK REQUIRED. R & R RT WING DUMP VLV. OPERATIONS CHECKED RT WING DUMP VLV IAW MM. DUMP VLV ACCESS PANEL INSTALLED & SEALED.