What was found
AFT FUSELAGE WASTE TANK AREA STATION 1986 BILGE CTR LINE AFT SIDE OF FRAME. SHEAR CLIP EXFOLIATION CORROSION. REMOVED SHEAR CLIP IAW SRM 51-31-01 VOL 2. REPLACED SHEAR TIE IAW DWG AGA3787. HEAT TREATED SPLICE ANGLE IAW DPS 7.00-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT FUSELAGE WASTE TANK AREA STATION 1986 BILGE CTR LINE AFT SIDE OF FRAME. SHEAR CLIP EXFOLIATION CORROSION. REMOVED SHEAR CLIP IAW SRM 51-31-01 VOL 2. REPLACED SHEAR TIE IAW DWG AGA3787. HEAT TREATED SPLICE ANGLE IAW DPS 7.00-1.