What was found
MAIN DECK FLOORBEAM UPPER FLANGE AT BS 1640 HAS SEVERAL CORRODED SPOTS. CORROSION REMOVED AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, DETAIL III, FIG. 101. REPLACED THE FLOORBEAM IAW SRM 51-40-02, AND DWG 146N5089. MAJOR REPAIR
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOORBEAM UPPER FLANGE AT BS 1640 HAS SEVERAL CORRODED SPOTS. CORROSION REMOVED AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, DETAIL III, FIG. 101. REPLACED THE FLOORBEAM IAW SRM 51-40-02, AND DWG 146N5089. MAJOR REPAIR