What was found
BS 1080 - 1100 LT CREASE BEAM WEB FOUND CORRODED. REMOVED IAW SRM 51-40-02 REV 114. NEW CREASE BEAM WEB FABRICATED IAW DWG 144N5210 SHT 01 REV & INSTALLED IAW DWG 144N5200 SHT 01 REV B. REPAIR CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1080 - 1100 LT CREASE BEAM WEB FOUND CORRODED. REMOVED IAW SRM 51-40-02 REV 114. NEW CREASE BEAM WEB FABRICATED IAW DWG 144N5210 SHT 01 REV & INSTALLED IAW DWG 144N5200 SHT 01 REV B. REPAIR CLASSIFIED AS MAJOR.