BS 1420 - 1440 RT CREASE BEAM WEB UPPER SURFACE FOUND CORRODED. REMOVED IAW SRM 51-40-02 REV 114. NEW CREASE BEAM WEB FABRICATED IAW DWG 146N5590 SHT 08 REV B & INSTALLED IAW DWG 146N5590 SHT 8 REV B. REPAIR CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1420 - 1440 RT CREASE BEAM WEB UPPER SURFACE FOUND CORRODED. REMOVED IAW SRM 51-40-02 REV 114. NEW CREASE BEAM WEB FABRICATED IAW DWG 146N5590 SHT 08 REV B & INSTALLED IAW DWG 146N5590 SHT 8 REV B. REPAIR CLASSIFIED AS MAJOR.