What was found
EMPENNAGE APU AIR INLET DOOR CUT OUT, SUPPORT ANGLE FOUND CORROSION BETWEEN BS 1790 - 1825, STRINGER 3R, AFTER APU AIR INLET DOOR HOUSING REMOVED. FOUND CORROSION OUT OF LIMIT IAW SRM 53-80-02 FIG 101 DETAIL IV REV 114. CORRODED SUPPORT ANGLE R & R NEW FABRICATED SUPPORT ANGLE IAW EA F-5310-T0316739 PART 1. REPAIR CLASSIFIED AS MAJOR.