What was found
MDC FLOORBEAM AT STATION 1681, UPPER CHORD UNDERSIDE SURFACES, HAS AREAS WITH CORROSION, AT & AROUND NUTPLATES, LBL 58 - RBL 58. REMOVED DAMAGE IAW SRM 51-10-02. CHECKED LIMITS FOUND AREA AT STATION 1681, RBL 24 TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101 DETAIL III. REPAIRED FLOORBEAM AT STATION 1681, RBL 24 IAW SRM 53-00-51 REPAIR NR 2 FIG 201. MAJOR REPAIR.