What was found
EMPENNAGE AREA INTERIOR COMPARTMENT, THERE IS CORROSION ON THE INTERIOR SKIN BETWEEN STATION 1806 - 1825 FROM STRINGER 25L - 27L. CORROSION REMOVED, FOUND OUT OF LIMIT AS PER SRM 53-00-01 FIG 101 DETAIL II REV 114. CORRODED SKIN REMOVED FROM STA 1787-1862 STR 25L-25R AND REPLACED NEW SKIN PN 148N3216Y1 SEE SNRM NO N01669 FOR DETAIL. REPAIR CLASSIFIED AS MAJOR