What was found
ON ARRIVAL, WALK AROUND CHECK FOUND LT NR 8 LE SLAT CABLE CUT IN TWO PLACES, SECOND & THIRD TRACK FROM MOST OTBD. R & R LT NR 8 LE SLAT EXTENSION & RETRACTION CABLES & PULLEYS IAW AMM 20-20-07-2, IPC 27-81-27-01 & 20-00-00-0 SMP. COMPLIED LOCKWIRE & LOCK CLIP IAW AMM 20-20-05-2. PERFORMED ADJUSTMENT THE LT OTBD SLAT DRIVE CABLES & FUNCTIONAL TEST OF THE SLAT RANGE OF MOVEMENT IAW AMM 27-80-00-5. ALL SYS WORKS NORMAL. INSTALLED ACCESS PANELS 519DB, 525AB, 527AB, 527DB, 527KB & 527AT. ALL WORKS WITH SASCO 2 AMTS. ACFT OK FOR SERVICE.