What was found
ON APPROACH, RT GEAR DOOR LIGHT REMAINED ILLUMINATED & GOT GEAR DISAGREE EICAS MSG. COMPLIED WITH QRH BOTH LIGHTS WENT OUT ON SHORT FINAL. RELEASED FOR SERVICE IAW MEL 32-30-01 CATEGORY C EXPIRATION 04 SEP 15. LANDING GEAR ACTUATION SYS INOPERATIVE. LANDING GEAR LOCKED DOWN. ADC VMO MMO SWITCH HAS BEEN SELECTED TO ALTN POSITION. R & R GEAR CONTROL LEVER MODULE IAW AMM 32-31-01-4, STILL REQUIRES OPERATIONS CHECK. CHANGED OUT HANDLE MODULE IAW AMM 32-31-01 401. OPERATIONS CHECKED GOOD WITH HYD MULE.