What was found
CABIN STATION 1420 - 1440 RT, CREASE BEAM WEB UPPER SURFACE CORROSION. CORROSION REMOVED IAW SRM 51-10-02 REV 115. REWORKED AREA EVALUATED, MATERIAL THICKNESS REMOVED 0.010", FOUND OUT OF 10% LIMIT IAW SRM 53-60-13 ALLOWABLE DAMAGE 1 FIG 101 REV 116. CREASE BEAM WEB REMOVED IAW SRM 51-90-02 REV 116. CREASE BEAM WEB REMOVED IAW SRM 51-40-02 REV 116. CREASE BEAM WEB FABRICATED & INSTALLED IAW DWG 146N5590 SHT 4 REV E. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.