What was found
AT 370 RECEIVED LEVEL 1 HIGH STAGE 3 OFF ALERT, FOLLOWED BY LEVEL 1 MANIFOLD 3 FAIL ALERT. PERFORMED QRH, RAN THROTTLE IN IDLE. REPLACED NR 2 ENG HIGH STAGE TEMP SENSOR IAW AMM 36-11-01-2. OPERATIONS CHECKED GOOD. PERFORMED PSC 1, 2 & 3 RTS IAW AMM 36-10-02-5. ALL TEST PASSED. RAN ENG 2 & 3 IAW JRH & CHECKED PNEUMATIC SYSTEMS IAW AMM 36-00-03-5, SATISFACTORY. REPLACED NR 3 MANIFOLD FAILURE DETECTION PRESS SWITCH IAW MM36-23-03-4.