What was found
CARGO FIRE EXTINGUISHER AGENT LOW LIGHTS ON FOR BOTTLE 1. REASON CODE, REMOVAL FROM ACFT ONLY, NO INSTALLATION. REMOVED LOWER CARGO COMPARTMENT FIRE EXTINGUISHER CONTAINER IAW AMM 26-22-01-4, ALL HARDWARE IS ATTACHED TO THE RACK. REASON CODE, INSTALLATION ON ACFT ONLY, NO REMOVAL. REPLACED LOWER CARGO FIRE BOTTLE AS NEEDED IAW MM 26-22-01-4. OPERATIONS CHECK IAW AMM 26-22-02-5. OPERATIONS CHECKED NORMAL. ACFT OK FOR SERVICE.