What was found
AT 40 KTS, MASTER CAUTION, AUTO THROTTLE DISC, ALERT APPEARED ON EICAS. REJECTED TAKEOFF. CLEARED MSG WITH AUTOTHROTTLE DISCONNECTS ON THROTTLE QUADRANT. THRUST MANAGEMENT SYS & AUTO THROTTLE SYS INOPERATIVE. THRUST MANAGEMENT SYS & THROTTLE SYS INOPERATIVE. PERFORMED T/S AND TEST ITEM 02,05,10 PER FIM 22-03 FAULT TREE 828, FIM 22-03 FAULT TREE 830 AND FIM 22-03 FAULT TREE 835,NO FAULT FOUND,ALL TEST PASSED. PERFORMED TEST MCDP ITEM 30 AND 40 FOR LLM IAW AMM 22-00-02-2.TEST PASSED.OPS CHECK OK. ACFT STILL CAT 3.