What was found
LEFT PYLON LOWER SPAR CTR STIFFENER, BETWEEN RIB 9 & 10 FOUND CRACK. COMPLIED WITH EA 6-5450-T0324873 PT 1, REPAIRED LT PYLON LOWER SPAR CENTER STIFFENER. THIS REPAIR WAS CATEGORY C. REPAIR LIFE LIMITATION 6 MONTHS. LIFE LIMITATION MAY BE FURTHER EXTENDED AFTER DETAILED ANALYSIS. MAJOR REPAIR IAW GMM 6-2-100.