What was found
MAIN DECK AREA LEFT SIDE BETWEEN STATION 1381-1401 STRINGER 17L LONGERON HAS CORROSION. LONGERON FOUND OUT OF LIMITS IAW SRM VOL I 53-00-01 FIG 1B. REMOVED AND REPLACED LONGERON IAW SRM VOLII 51-31-01 AND 51-33-01 AND DRAWING AEA 0220-1. LONGERON FABRICATED ON T16/1236701 IAW DRAWING AEA 0220-1. ORIGINAL LONGERON THICKNESS .090 AFTER REWORK .071, OUT OF LIMITS IAW SRM 53-00-07. INSTALLED NEW LONGERON STA 1381-1401 STR 17L IAW SRM 51-31-01 VOL II. MAJOR REPAIR.