What was found
LEFT WING OTBD FLAP, OTBD FWD HINGE BRACKET SIDE ATTACH LOWER BORE CORRODED. FOUND EXCEEDED LIMITS IAW CMM 57-44-09. OVERSIZE BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-T0330789, PART 1, STEP 1C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT WING OTBD FLAP, OTBD FWD HINGE BRACKET SIDE ATTACH LOWER BORE CORRODED. FOUND EXCEEDED LIMITS IAW CMM 57-44-09. OVERSIZE BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-T0330789, PART 1, STEP 1C.