WHILE DESCENDING AT APPROX 17000 FT, ECAM SHOWED NR 2 IDG LOW OIL PRESSURE . DISCONECTED THE NR 2 IDG IAW ECAM AND REFERRED TO QRH PROCEDURE. FOUND IDG SIGHT GAGE TO INDICATE FULL OIL, ELECTRICAL CONNECTIONS SECURE AND DPI INDICATOR SET. REMOVED CONNECTORS, VISUALLY INSPECTED AND FOUND TO BE CLEAN, SECURE AND NORMAL. R & R NR 2 IDG, LEAK AND OPS CHECK NORMAL IAW AMM 24-11-11-04-01.