What was found
L-1 DOOR SLIDE PRESSURE PRESS TO TEST LIGHT STAYS ON. CLEANED PLUG ON RECEPTACLE WIRING, OPS CK NORMAL IAW MM 25-61-04-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L-1 DOOR SLIDE PRESSURE PRESS TO TEST LIGHT STAYS ON. CLEANED PLUG ON RECEPTACLE WIRING, OPS CK NORMAL IAW MM 25-61-04-5.