What was found
GOUGED DENT IN SKIN BS 1540 - 1560, 3 INCHES BELOW STRINGER 3L TO 5 INCHES ABOVE STRINGER 4L. FOUND TO BE OUT OF LIMITS, CUT OUT DAMAGE, FABRICATED REPAIR DOUBLER AND INSTALLE IAW SRM 530-00-01-2R REPAIR 16.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GOUGED DENT IN SKIN BS 1540 - 1560, 3 INCHES BELOW STRINGER 3L TO 5 INCHES ABOVE STRINGER 4L. FOUND TO BE OUT OF LIMITS, CUT OUT DAMAGE, FABRICATED REPAIR DOUBLER AND INSTALLE IAW SRM 530-00-01-2R REPAIR 16.