What was found
HFEC SURFACE INSPECTION ON CARRIED OUT ON RH NLG TRUNNION FITTING STOP DRILL HOLE AREA AND FOUND 01 EA CRACK APPROXIMATELY 3/8 INCH IN LONG AS MARKED. CRACKED AREA AT RH NLG TRUNNION FITTING AT STA Y=595 REPAIRED AS PER SRM 53-10-14- 2R REPAIR 2 FIGURE 202 INITIAL INSPECTION TO BE CARRIED OUT AT 1,500 FLT CYCLES AND REPETITIVE INSPECTION TO BE CARRIED OUT AT 1,500 FLT CYCLES AS PER SRM 53-10-14-2R TABLE 201 FIGURE 202/ REPAIR 2 REQUIREMENTS. REPAIR CLASSIFIED MAJOR PER GMM 6-2-100