EMER LT BAT 1 LO. T/S USING FIM 33-50-00-810 FOUND EMERG PWR SUPPLY AT FAULT. REMOVED AND REPLACED PWR SUPLY IAW MM 33-51-01-4 AND OPS CHECK PER 33-51-01-5 OPS VERIFED NORMAL. A/C OK FOR SERVICE.