Service difficulty report · Circuit Breaker · Boeing 75723A

Difficulty date
August 20, 2018
Submitted
August 23, 2018
Operation
Air carrier
Aircraft
N922FD
Make and model
Boeing 75723A
Aircraft serial
24293
Aircraft time
71,088 hours, 25,764 cycles
Part
Circuit Breaker
Condition
Weak
Location
Door Indicator
Stage of operation
IN
How discovered
V
Nature of condition
P
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING A TRANSIT CHECK, FOUND THE CARGO DOOR INDICATOR LIGHT CIRCUIT BREAKER A30 ON THE P11, OPEN AND IMPOSSIBLE TO CLOSE. DURING TROUBLESHOOTING, FOUND THE CARGO DOOR INDCATOR CIRCUIT BREAKER WEAK. R & R THE CIRCUIT BREAKER IAW SWPM 20-30-00. PERFORMED A MAIN CARGO DOOR ADJUSTMENT TEST IAW AMM 52-32-00-2. ALL TESTS PASSED. ACFT OK FOR SERVICE.