What was found
LOWER FWD FIRE INDICATION. AGENT DISCHARGED. INSTALLED LOWER CARGO COMPARTMENT FIRE EXTINGUISHER BOTTLES 1 AND 2 IAW AMM 26-22-01-4. FAILS STEP 4 ELECTRICAL CONTINUITY TEST, ALSO REQUIRES STEP 5, FIRE EXTINGUISHER DEPLOYMENT LINES ROUTING AND LEAK CHECK. COMPLIED WITH STEP 5 AND 6, FIRE EXTINGUISHER DEPLOYMENT LINES ROUTING AND LEAK CHECK. ROUTING AND LEAK CHECK IS GOOD REF MM 26-22-05-2. R/I CP P1-2288 IAW WDM 26-22-01. ALL OPS CHKS PREVIOUSLY C/W. C/W ELECTRICAL CONTINUITY TEST OF THE LOWER CARGO FIRE EXTINGUISHER CONTAINER DISCHARGE CARTRIDGE AND OPS NORMAL IAW 26-22-01-5 LOWER CARGO FIREX DISCHARGE CIRCUITS - ADJUSTMENT/TEST.