What was found
MAIN CARGO COMPARTMENT FLOOR STRUCTURAL SUPPORT IS BROKEN LOCATED AT BODY STATION 1259 AT RH SIDE X82 AT AREA LOCATED UNDERNEATH MAIN CARGO COMPT. FLOOR PANELS 252LF AND 262BF. REMOVED CRACKED ANGLE FLOOR SUPPORT IAW MD-10 SRM 51-31-01. RECEIVED FABBED FLOOR SUPPORT ON TRAVELER # T18/1366685 LOCATED, DRILLED AND DEBURRED HOLES IN FLOOR SUPPORT IAW MD-10 SRM 51-31-01. TREATED AND PRIMED FLOOR SUPPORT IAW MD- 10 SRM 51-21-01. INSTALLED FABBED FLOOR SUPPORT IAW MD-10 SRM 51-31-01.MAJOR REPAIR