SUB BEAM AT STA 580 IS CRACKED. TRIMMED ENTIRE UPPER FLANGE OF THE BS 580 FLOOR BEAM SPLICE. FABRICATED REPAIR ANGLE AND RADIUS STRAP AND INSTALLED IAW EA F-5310-T0343027 P-1.