What was found
ON PREFLIGHT L1 DOOR SLIDE CIRCUITRY LIGHT REMAINS ILLUMINATED. WHILE TRYING TO COMPLY WITH MEL 25-61-01 FOR THE "PRESS-TO-TEST" INDICATION, METHOD "A", THE TEST FAILED STEP 1A 4B, DISCONTINUED WITH MEL 25-61-01 PROCEDURES AND RETURNED L1 DOOR BACK TO ITS ORIGINAL CONFIGURATION. L1 DOOR SLIDE PRESSURE INDICATOR PRESS TO TEST SWITCH IS TESTING NORMAL, REF MM 25-61-03-5. CONTINUITY CHECK IS OK, REF FIM 25-61-00-2. OK FOR SERVICE.