Service difficulty report · Shutoff Valve · Doug MD11F

Difficulty date
May 3, 2019
Submitted
May 3, 2019
Operation
Air carrier
Aircraft
N592FE
Make and model
Doug MD11F
Aircraft serial
48550
Aircraft time
82,154 hours, 18,273 cycles
Part
Shutoff Valve
Part number
AV24E1162
Part serial
717
Condition
Failed
Location
Elevator
Part time
54,676 hours, 13,875 cycles
Stage of operation
CL
How discovered
O
Nature of condition
K
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDIS 592 29-02 3353 03MAY19 IND FACT U LOGPAGES:3094152 DURING CLIMB OUT TO FL 390 WE RECIVED A LVL 1 HYD 3 ELEV OFF ALERT NO.3 QUANTITY WAS 4.5.W/3-2 NRMP INOP. DURING CRUISE QTY LEVEL WENT TO 4.1. DESCENT INTO IND WE CONFIGURED W/FLAPS 15 AND GEAR DOWN QTY WENT TO 2.3 ON NR 3 CONFIGURED A/C W/ FLAPS 35 AND GEAR DOWN QTY ON NR 3 REMAINED AT 2.3 LANDED A/C UNEVENTFULLY AND TAXIED CLEAR OF RWN 23R FLUID WAS LEAKING NEAR THE ELEVATOR, WE STOPPED A/C AND WAS TOWED INTO GATE. FACT 03MAY19 05:56 IND U REMOVED AND REPLACED NON-REVERSIBLE MOTOR PUMP SHUT-OFF VALVE IAW AMM CH 27-26-40-4-0. LEAK CHECK GOOD.