Service difficulty report · Sequence Valve · Airbus A310324

Difficulty date
May 31, 2019
Submitted
June 6, 2019
Operation
Air carrier
Aircraft
N807FD
Make and model
Airbus A310324
Aircraft serial
492
Aircraft time
67,958 hours, 18,363 cycles
Part
Sequence Valve
Part number
A252801
Part serial
M460
Condition
Misaligned
Location
Rt Mlg
Part time
11,896 hours, 7,788 cycles
Stage of operation
AP
How discovered
O
Nature of condition
S
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

6685 ON GEAR EXTENSION RECEIVED UNSAFE INDICATION FOR RT MLG ON SYS 1 SYS 2. COMPLIED WITH QRH PROCEDURES AND LG GRAVITY EXTENSION CHECKLIST. GEAR DOORS REMAINED OPEN, UNEVENTFULL LANDING KLRD. (ON LOW APPROACH, TOWER CONFIRMED RT MLG HUNG UP). TROUBLESHOT IAW FIM 32-30-00 FIG 115. FOUND RH GEAR SEQUENCE VALVE RIG HOLE NOT LINING UP/OUT OF RIG. REMOVED AND REPLACED RH GEAR SEQUENCE VALVE IAW AMM 32-31-37-04. LEAK AND OPS CHECKS GOOD.