What was found
COCKPIT STA.345 BETWEEN LBL5-LBL 24 FLOORBEAM CORRODED. CORROSION ON EXISTING FLOORBEAM "T "CAP REPAIR OUT OF LIMITS, REMOVED EXISTING "T" CHORD ANGLE & REPAIR SPLICES, CUT OUT FLOORBEAM FROM RBL.12 TO RBL.53,FABRICATED NEW "T" CHORD & REPAIR PARTS & INSTALLED NEW FLOOR BEAM "T" CAP REPAIR AT STA.345 FWD ENTRY FLOOR IAW SRM 53-00-51-2R REPAIR 10 DETAIL II, FROM LBL.52 TO RBL.53.