What was found
FIRE AT EXTERNAL POWER CONNECTION BURNED AND MELTED AIRCRAFT EXTERNAL POWER RECEPTACLE AND COMPONENTS. INSTALLED EXTERNAL POWER RECEPTACLE REFERENCE AMM 24-41-03-4. COMPLETED INSTALLATION OF EXTERNAL POWER PANEL REFERENCE DRAWING AAN7220 AND AMM 20-50-02-2. APPLIED EXTERNAL POWER REFERENCE MD-11 AMM 24-40-00-2 WITH NO DEFECTS NOTED. STARTED APU REFERENCE JRH AND ACCOMPLISHED MULTIPLE POWER TRANSFERS WITH NO DEFECTS NOTED. INSTALLED FLOOR PANEL 123HF REFERENCE AMM 53-21-04-4. STILL REQUIRES INSTALLATION OF NYLON CORD AND SEALANT. INSTALLEDD NYLON CORD AND SEALED TO FLOOR BOARD. REF AMM 53-21- 04-4.