What was found
RIGHT WING, LOWER LEADING EDGE WAS CRACKED ON PANEL LAND, AFT OF NR 9 SLAT TRACK. REMOVED AND REPLACED DAMAGED SUPPORT ARB2933-50 IAW DWG ARB2933 AND SRM 51-33-01 V2 AND SRM 51-35-01 V2 REMOVED DAMAGED DOUBLER ARB2933-50. REMOVED DOUBLER ARB2933-50 IAW SRM 51-31-01. MATERIAL VERIFIED MA3941560 7075T6 .090., FABRICATED ARB233-50 IAW DWG ARB 2933. ALODINED AND PRIMED IAW SRM 51-21-01. INSTALLED SUPPORT IAW DWG 2933, SRM 51-33-01, AND SRM 51-35-01.