What was found
LOWER FUSELAGE HAD A DENTED AREA AT BS 513, BETWEEN STRINGERS 28L AND 29L. EVALUATED DENTED AREA AND FOUND THE AREA TO HAVE TWO GOUGES IAW IAW SRM 51-10-02-0G, AND BLENDED AREA AND FOUND MINIMUM THICKNESS REMAINING OF SKIN AREA .030. FOUND TO BE OUT OF LIMITS IAW SRM 53-00- 01-1A DET II. CUT OUT AREA OF DAMAGE IAW SRM 53-00-01-2R, FIG 1, DET I, REPAIR 28. FABRICATED A DOUBLER AND FILLER. INSTALLED THE REPAIR IAW SRM 53-00-01-2R, REPAIR 28.