What was found
MAIN DECK CARGO COMPARTMENT AFT FLOOR SUPPORT FOUND WITH CORROSION AT STATION 1970 X = - 56. MAIN DECK CARGO COMPARTMENT AT AFT FLOOR SUPPORT STATION 1970 X = - 56, CORROSION REMOVED AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 ALLOWABLE DAMAGE. CORRODED AFT FLOOR SUPPORT REMOVED AND REPLACED FROM STATION 1887 TO STATION 2007 X = - 56 AS PER SRM 51-31-01-0G. AFT FLOOR SUPPORT FABRICATED BY MACHINING AS PER DRAWING AGA 7551 REVISION G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.