As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
01 EACH CRACK INDICATION APPROXIMATELY 1 INCH LENGTH FOUND DURING X-RAY INSPECTION AT STATION Y = 6-100 , LONGERON - 3 LEFT CENTER SPLICE FORWARD SECTION BETWEEN FASTENER NUMBER 6 AND NUMBER 7 . CRACKED LONGERON SPLICE AT STATION Y = 6-100 , LONGERON 3 LEFT . REMOVED AND REPLACED AS PER SRM 51-33-01-0G . LONGERON SPLICE FABRICATED BY MACHINING AS PER DOUGLAS DRAWING A6A7112 REVISION A . REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 .