What was found
LANDING GEAR: DURING CARRYING OUT REPAIR OF NOSE LANDING GEAR LEFT HAND TRUNNION FITTING, FOUND FITTING HOLE WITH PITTING CORROSION. CORROSION AT NOSE LANDING GEAR LEFT HAND TRUNNION FITTING HOLE REWORKED AND FOUND EXCEED LIMIT AS PER SRM 53-10-14-2R FIGURE 201. REPAIR BUSHINGS 02 EACH FABRICATED BY MACHINING AND INSTALLED AS PER SRM 53-10-14-2R REPAIR 1 AND EA 1-5310-T0351577 PART 1 STEP 5A AND STEP 5, TITLE: FUSELAGE- MAINFRAME- LT TRUNNION FITTING- CORROSION FOUND ON BORE HOLE AT Y= 587, Z= 109.5. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.