What was found
LOWER CTR CARGO PIT AT DOOR ENTRY STA. 1750 CEILING FLOOR BEAM HAS CORROSION ON LOWER LEG OF I-BEAM REMOVED & REPLACED CEILING FLOOR I-BEAM LOWER LEG AFA7509-5, REF. DAC DWG 7509 & MD10 SRM 51-31-01, VOL 2, PG 23
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER CTR CARGO PIT AT DOOR ENTRY STA. 1750 CEILING FLOOR BEAM HAS CORROSION ON LOWER LEG OF I-BEAM REMOVED & REPLACED CEILING FLOOR I-BEAM LOWER LEG AFA7509-5, REF. DAC DWG 7509 & MD10 SRM 51-31-01, VOL 2, PG 23